Thermal Image UK

SURVEY 001 South Lanarkshire · est. 02 / 2008

See energy loss and stop it.

Thermal imaging and air tightness testing for homes and commercial buildings across Scotland and the north of England — from an independent practice in Strathaven.

  • Feb 2008independent
  • StrathavenSouth Lanarkshire
  • Level 1 & 2air tests
  • RetrotecUK sales & support
FIG. 01 GABLE ELEVATION
A gable wall drawn as a temperature scale A line drawing of a gable-end wall with two windows and a soil pipe. A soft warm glow sits along the eaves and a cold patch at the lower corners and around the windows and pipe. Numbered markers 01 to 03 point to the eaves, a window reveal and the pipe. 01 02 03
A generic gable, not to scale. Readings withheld — survey data belongs to the client.
  • 01Eaves— °C
  • 02Window reveal— °C
  • 03Soil pipe— °C

01 — Brief

Two tests, one leak.

A camera finds where heat leaves. A fan measures how much air goes with it. Neither one on its own tells you what to fix — which is why the two are booked together.

§ 01Thermography + blower door, one visit, one report.

The camera

A surface reading

  • Shows temperature differences across the fabric: missing insulation, wet insulation, thermal bridges.
  • Shows the shape of a leak — a cold streak at a junction, a plume at a pipe.
  • Needs a temperature difference across the wall, and a trained eye to read it.

Does not give you: a leak rate, or a certificate.

INSIDEwarm air, under pressure

A wall section with a pipe through it A plan section. Warm air sits above, cold air below. A pipe passes through the wall and a dashed line shows air escaping around it into the cold side, where cold rings spread from the penetration.

OUTSIDEcold surface, lower pressure

The fan

A measured rate

  • Measures air permeability for the whole envelope at a controlled pressure difference.
  • Finds the paths with smoke, so a leak can be pointed at rather than guessed.
  • Gives you the figure the certificate and the building control file need.

Does not tell you which surface is cold, or where the heat goes next.

Together the image says where, the fan says how much. Air tightness testing

02 — Survey

Four ways to read a building.

Every job starts with a survey of the fabric — the walls, the roof, the junctions and the holes in them. These are the four services, and what each one is actually for.

§ 02Domestic and commercial · Scotland and the north of England.

Services, what each one finds, and when you need it
Service What it finds When you need it Link
01Thermal imaging Temperature differences across the fabric: missing or wet insulation, thermal bridges, and the cold shape of an air path. A cold room, a damp patch, a new-build handover — or before you buy.
02Air tightness testing Air lost through leaks in the building fabric, measured at a controlled pressure difference. Level 1 and Level 2 tests. Building compliance, a Passivhaus build, or a house that feels draughtier than it should.
03Heat loss surveys Where the heat is leaving, room by room and junction by junction, read against the images rather than guessed at. Before you specify insulation, glazing or a new heating system.
04Retrotec equipment Sales and support for the full Retrotec blower-door range in the UK — 300 series through to 6000 series fans. You run your own tests and need the fan, the gauge and someone who knows them.

03 — Images

What the camera sees.

A thermal image is not a photograph of heat. It is a map of surface temperature, with the scale attached — and it means nothing without the daylight frame beside it.

§ 03Images from Thermal Image UK’s own site.

Thermal image of a gable wall: a cool roof surface, warmer wall faces in yellow and red, and colder window openings THERMAL
Gable wall, in a thermal palette. The roof surface reads cool; the wall faces read warm; the window openings read colder than the wall around them. The caption describes only what is visible — no reading is attributed to a named building.

04 — Air test

The fan that proves it.

A blower door holds a set pressure difference across the whole building and measures the air needed to keep it there. That figure is the air permeability — and it is the one that goes on the certificate.

§ 04Level 1 & 2 · BS EN · Elmhurst scheme.

A Retrotec blower door fan set into a doorway aperture, sealed with a red sheet
A blower door fan set into a doorway aperture, with the rest of the opening sealed. Photograph from Thermal Image UK’s own site.

The full Retrotec range is used — from the small 300 series fans to the 6000 series — so the same team can test a single house, a school, a community centre, a retail unit or a large commercial warehouse. Passivhaus builds included.

Equipment
Retrotec blower-door fans, 300 to 6000 series
Scheme
Audited member of the Elmhurst Airtightness Scheme
Standard
Air tightness testing to BS EN standards
Tests
Level 1 and Level 2, residential and commercial
Certificate
May be issued the same day, when we can

“We have air tested thousands of buildings over the last 15 years.”

Thermal Image UK, on its own site

05 — Report

Signed by the person
who did the test.

Thermal Image UK was formed in February 2008 by Tom Barbour, after senior roles at Scottish Power and Prudential UK. The company is independent, based in South Lanarkshire, and works across Scotland and the north of England.

§ 05Founder & director · since 02 / 2008.

Tom Barbour, founder of Thermal Image UK
Tom Barbour, founder. Photograph from Thermal Image UK’s own site.

Tom is a Certified Level 2 Thermographer with the Infrared Institute, holds a PCN certificate with the British Institute of Non-Destructive Testing, and is an approved Level 2 Air Tightness Tester registered with the Elmhurst Airtightness Scheme. He also trains air tightness testers for Infrared Training Ltd.

“Tom is the only registered Level 2 thermographer in Scotland.”

Thermal Image UK, on its own site

The team

Andrew McCulloch joined in 2018 and is a Level 2 Air Tightness Tester registered with the Elmhurst Airtightness Scheme. He runs heat loss surveys for homeowners, and much of his air testing and thermal imaging is on houses and community buildings along Scotland’s west coast islands.

  • BINDT · PCN
  • Elmhurst Airtightness Scheme
  • Passivhaus Trust
  • Infrared Training Ltd

06 — Reviews

“Great service, very professional. Up to date equipment and extremely experienced staff.”

Andrew Scott, Argyll And Bute

Published on Thermal Image UK’s own customer reviews page, and quoted here as it appears there.

Read the customer reviews
Two members of the Thermal Image UK team standing beside a van lettered with the company name and the line See Energy Loss and Stop It
The team and the van. Photograph from Thermal Image UK’s own site.